Introduction :
LS4808 and LS4816 are all new speaker line monitoring unit, replacing the long running LS4600. Now available in 2 versions ; 8 and 16 channels types.
With their new processor and measurement algorithm, they are now able to perform tasks faster with better accuracy. Additional features included were trigger monitoring, which can be linked to timer for preset times activation.
Similar to its previous model, they provide reliable speaker circuit monitoring for ground leakage, short and open circuit using impedance measurement method, thus eliminating the use of blocking capacitors and end line resistors.
Features:
-
-
8 / 16 channel versions
-
Basic and advance level setting
-
Sensitivity setting
-
Impedance measurement method ; end line resistors, block capacitors not required
-
Faulty circuit disconnection option
-
Built in impedance meter ; 10 to 10K Ohm
-
Fault alert bicolour LED with buzzer
-
Interval detection from 1m to 48 hrs
-
Remote detection activation
-
Short burst signal for lesser interruption
-
Aux contact for 24V overriding during activation period
-
RS485 for remote monitoring
-
Technical Specifications 🙁 LS4808 / 4816 ) :
Power requirement :
Voltage 24V DC
Consumption 3.8 / 4.9 W
Processor 32 bit ARM processor
Capacity 8 / 16 channel
Detection range 10 to 10K Ohm
Load measurement 10W to 1000W 100V Line
Accuracy +/- 3%
Pilot tone injection 1 KHz
Tone level 5V sine
Detection period 0.5 sec
Triggering Auto / manual
Detection interval Preset 1m to 48 hrs
Sensitivity User preset
Indicators Normal, Buzzer, Auto
LCD display 2 x 16 charactors
Audible alert Buzzer with off option
Dry contact 3A
DC output 24V DC overriding
Dimensions (mm) LS4808 : 482 X 44 X 180
LS4816 : 482 x 88 x 180
Weight 2.4 / 3.1 kg